Home » News and Updates » SBF Analyzer: Verify File Contents and Read Front-End Gain

SBF Analyzer: Verify File Contents and Read Front-End Gain

SBF Analyzer: Verify File Contents and Read Front-End Gain

SBF Analyzer answers two questions about any recorded Septentrio SBF file: which SBF blocks it actually contains, and whether the receiver’s RF front end was healthy while the file was being logged. Both live in the same free tool bundled with RxTools. Open the file, tick General File Information, press Analyze and read the Message statistics tab for the block inventory; then tick Front End Gain (the file must contain the ReceiverStatus block) to plot the AGC gain of every GNSS band over time. On an AsteRx-U, AGC readings inside 15–50 dB are healthy, above 50 dB means too little net gain reaches the receiver input, and below 15 dB means too much — converted with net gain = 65 dB − AGC gain.

Source: this guide is based on Septentrio’s knowledge-base articles Verifying the Contents of an SBF File and SBF Analyzer: Front End Gain, rewritten with Eview field notes. Screenshots: Septentrio. SBF Analyzer is part of Septentrio RxTools.

Why the block inventory comes first

SBF (Septentrio Binary Format) stores data as binary blocks, and each block carries one class of information: PVTGeodetic holds the position solution, ReceiverStatus holds receiver and front-end status, and so on. Everything you do later with the file depends on which of those blocks were switched on during the recording.

That is why the front-end gain step has a hard prerequisite. A recorded SBF file cannot be retro-fitted with a block it never contained, so if ReceiverStatus is missing you have to enable it in the receiver’s SBF output settings and log again. Checking the inventory takes about a minute and saves a wasted analysis session.

Step 1: open the SBF file

Use the file-browse button in SBF Analyzer, as shown in Figure 1. If you already know where the file sits, the faster route is Windows Explorer: right-click the file and choose Analyze SBF (Figure 2). Both paths open the identical file in the same application.

SBF Analyzer opening an SBF file with the file browse button

Figure 1. Opening an SBF file from SBF Analyzer. Image courtesy of Septentrio.

Windows Explorer context menu with the Analyze SBF option

Figure 2. The Analyze SBF entry in the Windows Explorer context menu. Image courtesy of Septentrio.

Step 2: read the block inventory in Message statistics

Select the General File Information plot, then click Analyze (Figure 3). In the result window, switch to the Message statistics tab (Figure 4). Each SBF block that the file contains is listed with its record count.

SBF Analyzer General File Information plot with the Analyze button

Figure 3. General File Information selected, ready to Analyze. Image courtesy of Septentrio.

The example in Figure 4 holds 970 PVTGeodetic blocks at 1 Hz, which works out to roughly 970 seconds of recording. That single number verifies two things at once: the block you wanted really was enabled, and the output rate matches the configuration you intended. A 20-minute test that should show 1,200 records but shows 60 is a recording problem, not a positioning problem — and you want to know that before you start interpreting coordinates.

SBF Analyzer Message statistics tab listing SBF blocks and record counts

Figure 4. Message statistics lists every SBF block with its record count — 970 PVTGeodetic records at 1 Hz here. Image courtesy of Septentrio.

Step 3: generate the Front End Gain plot

Every Septentrio receiver carries an AGC (automatic gain control) circuit in its RF front end. The AGC regulates the amplitude of the GNSS signal arriving at the antenna port so the level entering signal processing stays inside the optimum window. Plotting the AGC gain of each band over time gives the Front End Gain view, and that curve describes the RF chain — antenna, cable, splitter, receiver front end — rather than the position solution.

To draw it, confirm ReceiverStatus is present (Step 2), tick the Front End Gain checkbox shown in Figure 5 and press Analyze.

SBF Analyzer plot list with the Front End Gain checkbox selected

Figure 5. The Front End Gain checkbox in SBF Analyzer’s plot list. Image courtesy of Septentrio.

Step 4: convert AGC gain into net gain

Each receiver’s hardware manual states the net gain that should be present at the antenna input. Net gain is the total pre-amplification of the whole RF distribution network: the active gain of the antenna LNA minus the losses of coax, splitters, DC blocks and any other components between antenna and receiver. For a single band, the plot reading converts directly:

net gain [dB] = 65 dB − AGC gain [dB]

AsteRx-U is the worked example in Septentrio’s documentation: its net gain should sit between 15 dB and 50 dB, so the corresponding AGC window is also 15–50 dB. The bounds follow from the same formula — maximum AGC gain 65 − 15 = 50 dB, minimum AGC gain 65 − 50 = 15 dB.

AGC gain read from the plotNet gain at the input (AsteRx-U example)What it means
Above 50 dBBelow 15 dBToo little power at the receiver input: excessive cable loss, a splitter, a DC block, or an antenna that is not connected properly
15–50 dB15–50 dBInside the range the hardware manual expects
Below 15 dBAbove 50 dBNet gain too high: too much pre-amplification in the chain

The 15–50 dB figures are the AsteRx-U example from the source documentation. For an HB56 (Septentrio mosaic-X5 inside) or any other model, take the net-gain range from that model’s own hardware manual and apply the same formula — do not copy the AsteRx-U numbers across.

Step 5: read a healthy plot, then a faulty one

Figure 6 shows a file recorded by a dual-antenna AsteRx-U. The upper plot is AGC gain in dB; the lower plot is pulse blanking in percent. The legend on the right switches individual bands on and off, and on a dual-antenna receiver every band produces two curves — one for the main antenna input, one for the auxiliary input.

Front End Gain plot of a dual-antenna AsteRx-U with flat AGC curves inside the expected range

Figure 6. Front End Gain plot from a dual-antenna AsteRx-U: main-input curves inside range, auxiliary input above the upper limit with no antenna connected. Image courtesy of Septentrio.

In this example every main-input curve sits inside the 15–50 dB expectation. Every auxiliary curve sits above the 50 dB limit, which means that input is either heavily attenuated or simply not connected — in this recording the auxiliary port had no antenna attached. Across the whole file the curves stay flat, with no spikes and no drops: that is what a healthy RF chain looks like.

A practical reading order helps when the plot is unfamiliar. Look at the overall level first: a curve group that is out of bounds points at the antenna and cabling. Then look at stability: a single jittery curve points at a bad connector or an intermittent contact. Only then compare bands against each other, because a drop confined to one band is a statement about that band’s RF environment.

What interference looks like on the AGC curves

Interference can enter the antenna input from equipment inside the vehicle or from a transmitter in the surroundings. Extra power at the antenna port forces the receiver to reduce its amplification, so the AGC gain falls — which makes the Front End Gain plot one of the most direct interference indicators available in a recorded file.

Interference usually affects only part of the spectrum. The documented example is a 1,240 MHz amateur radio transmitter that can disturb GLONASS L2 (1,237–1,253 MHz) while leaving GLONASS L1 (1,593–1,610 MHz) untouched. That shape — one band down, its neighbours steady — is itself the clue to the source.

Front End Gain plot showing a GPS L1/E1 AGC gain dip while other bands stay flat

Figure 7. A GPS L1/E1 AGC dip from 26 dB to 14 dB while GPS L2 and E5b/B2I stay flat. Image courtesy of Septentrio.

Figure 7 plots GPS L1/E1 (green), GPS L2 (purple) and E5b/B2I (brown). GPS L1/E1 falls intermittently from 26 dB to as low as 14 dB, while GPS L2 and E5b/B2I stay flat within 1–2 dB. The conclusion is a GPS L1 band interference source, not a receiver fault.

Putting it to work on HB56 logging

The workflow transfers unchanged to Eview receivers, because the logging format is the same one the tool reads. HB56 (Septentrio mosaic-X5 inside) writes raw SBF to its SD card, so a field complaint about “degraded fix” can be checked the same day: pull the log, confirm ReceiverStatus and PVTGeodetic are both present, then read the AGC curves before touching the installation. If the front end is starved the fix is in the RF chain; if one band dips while the rest are steady, the fix is the interference environment. HB56H (mosaic-H), the dual-antenna heading version, plots two curves per band exactly like the AsteRx-U example — useful for spotting a bad secondary antenna feed that still produces a heading solution.

Eview receivers that log SBF for this check

Send us your SBF log and we will read the Front End Gain for you: sales@gnss-solutions.com

Frequently asked questions

Does SBF Analyzer cost anything?

No. It ships with RxTools, the same free package that handles receiver configuration and firmware, so no extra licence or converter is needed.

Why is the Front End Gain checkbox greyed out or empty?

The file has no ReceiverStatus block. Confirm it in Message statistics; if it is missing, enable ReceiverStatus in the receiver’s SBF output settings and record again.

Can I evaluate an old log without ReceiverStatus?

No. The AGC history is only stored in ReceiverStatus, so it cannot be reconstructed from other blocks after the fact.

Is AGC above 50 dB always a hardware fault?

Not necessarily. It means net gain at the input is below the manual’s range, which a long cable run, an added splitter or an unconnected port will all produce. Compare against the installed chain before blaming the receiver.

Which model’s net-gain range should I use?

The one in the connected receiver’s hardware manual. The 15–50 dB range quoted here belongs to AsteRx-U and is an example, not a universal specification.

Sources and image credits

This article is written in our own words from Septentrio’s original documentation. Figures 1–7 are reproduced unmodified from that material, image courtesy of Septentrio. The 15–50 dB range and the 65 dB conversion constant come from the AsteRx-U example; check the range for any other model in its hardware manual.

Need a receiver with SBF logging and a front end you can audit this way? Talk to our team at sales@gnss-solutions.com.

Related reading

Latest News & Announcement